• Периодические проверки

Foto Периодические проверки

Periodic Inspection / Inspection

Alberk QA Technic Control and Documentation Inc. provides professional services for all your periodic control processes with its expert staff and 15 years of industry experience.

It is a legal responsibility to carry out periodic checks.

In accordance with the law numbered 6331 published in the official newspaper with the number: 28339 dated June 30, 2012 ^ The employer provides the necessary control, measurement, examination and researches in terms of occupational health and safety to determine the working environment and the risks that employees are exposed to in this environment. In this context, the Regulation on Health and Safety Conditions for the Use of Work Equipment was put into effect instead of worker health and work safety in the Official Gazette No. 28628 dated Thursday, April 25, 2013. It has been finalized with some changes made after this process.

According to the regulation, pressure vessels and installations, Lifting and delivery equipment, Installations and Benches are subject to a minimum of 1 inspection per year, unless otherwise specified in the standards.

Electrical Installation, Grounding Installation, Lightning Rod

Pressure vessels and installations;

Steam boilers

1 Year if no time is specified in the standards

Heating boilers

1 Year if no time is specified in the standards

Portable gas cylinders (stitched, seamless)

3 Year if no time is specified in the standards

Portable acetylene tubes

TS EN ISO 10462 In the Time Specified in the Standard

Acetylene tube bundles with manifold

1 Year if no time is specified in the standards

Tube bundles with manifolds

1 Year if no time is specified in the standards

Liquefied gas tanks (LPG, etc.) (above ground)

10 years

Liquefied gas tanks (LPG, etc.) (underground)

10 years

LPG cylinders in use

1 Year if no time is specified in the standards

Compressed air tanks

1 Year if no time is specified in the standards

Cryogenic tanks

TS EN ISO 21009-2 In the Period Specified in the Standard

Tehlikeli sıvıların bulunduğu tank ve depolar

10 years

Lifting and transmission equipment

Lifting and / or forwarding vehicles (crane, mobile crane, tower crane etc.)

1 Year if no time is specified in the standards

Escalator and escalator

1 Year if no time is specified in the standards

Stacker (forklift, pallet truck, lift)

1 Year if no time is specified in the standards

Building Scaffolds

6 months if no time is specified in the standards

Installations;

Accumulator, Transformer

1 Year if no time is specified in the standards

Fire Installation and Hoses, Motopumps, Pipe Installation

1 Year

Fire Extinguisher

Within the periods specified in the TS ISO 11602-2 standard

Ventilation and Air Conditioning Installation

1 Year

Counters;

Maintenance and inspection of the benches once a year is sufficient. Inspections of the presses are carried out in accordance with TS EN 692 + A1 and TS EN 693 + A2 standards.